New microsensor measures volatile organic compounds in water and air on-siteSeptember 18, 2007Researchers at the Georgia Institute of Technology have developed a miniature sensor that uses polymer membranes deposited on a tiny silicon disk to measure pollutants present in aqueous or gaseous environments. An array of these sensors with different surface coatings could be used during field-testing to rapidly detect many different chemicals. Since this new sensor allows water and air samples to be analyzed in the field, it is an improvement over classical techniques that require samples be carried back to the laboratory for analysis. This research, funded by the National Science Foundation, was presented on August 20 at the American Chemical Society's 234th National Meeting. The heart of the disk-shaped sensor is a microbalance that measures the mass of pollutant molecules. "When pollutant chemicals get adsorbed to the surface of the sensor, a frequency change of the vibrating microbalance provides a measure of the associated mass change," said Oliver Brand, associate professor in Georgia Tech's School of Electrical and Computer Engineering. Cantilever-type balances, which move up and down like a diving board, are common when measuring the amount of a chemical in the gas phase. However, the mechanical vibrations of the balance used to detect the mass changes are damped in liquids, causing the sensitivity of the balance to decrease. Thus, Brand and graduate students Jae Hyeong Seo, Stuart Truax and Kemal Safak Demirci searched for structures whose vibrations were less affected by the surrounding medium. The researchers chose a silicon disk platform for the sensor. The disk shears back and forth around its center with a characteristic resonance frequency between 300 and 1,000 kHz, depending on its geometry. With proper actuation and sensing elements integrated onto the microstructures, Brand can electrically excite the resonator and sense these rotational oscillations. Since each sensor has a diameter of approximately 200-300 microns, or the average diameter of a human hair, an array of a dozen sensors is only a few millimeters in size. To determine how to selectively detect multiple pollutants in the same sample, Brand began collaborating with Boris Mizaikoff, an associate professor in Georgia Tech's School of Chemistry and Biochemistry and director of its Applied Sensors Laboratory. Mizaikoff and graduate students Gary Dobbs and Yuliya Luzinova selected commercially available hydrophobic polymers and deposited them as thin film membranes on the sensor surface. They continue to investigate innovative ways to consistently deposit the polymers at the disk surface, while ensuring sufficient adhesion for long-term field applications. "By modifying the silicon transducer surface with different polymer membranes, each sensor becomes selective for groups of chemicals," explained Mizaikoff. An array of these sensors, each sensor with a different chemically modified transducer surface, can sense different pollutants in a variety of environments ranging from industrial to environmental and biomedical monitoring applications. Brand and Mizaikoff aim to detect volatile organic compounds (VOCs) in aqueous and gaseous environments. VOCs are pollutants of high prevalence in the air and surface and ground waters. They are emitted from products such as paints, cleaning supplies, pesticides, building materials and furnishings, office equipment and craft materials. A common VOC is benzene, with a maximum contaminant level set by the Environmental Protection Agency (EPA) at five micrograms per liter in drinking water. Many VOCs are present at similar very low concentrations, so effective sensors must accurately measure and discriminate very small mass changes. "We've been able to measure concentrations among the lowest levels that have been achieved using this type of resonant microsensor," noted Brand. "While we have not achieved the required sensitivity yet, we are constantly making improvements." Brand and Mizaikoff have tested their sensor device in the laboratory by pumping water with specific pollutant concentrations through a simple flow cell device attached to the sensor. A typical test begins by flowing a water sample containing a known amount of pollutant over a sensor coated with a polymer membrane. When the sample flows through the cell, the mass of the microstructure increases, causing its characteristic vibration frequency, or resonance frequency, to decrease. By monitoring this resonance frequency over time, Brand and Mizaikoff can detect the amount of aromatic hydrocarbons such as benzene present in water. The researchers plan to run field trials to investigate the use of this new microsensor in aqueous and gaseous environments for rapid on-site screening of multiple pollutants. "With benzene and other VOCs high on the EPA priority pollutant list, it would be a major advantage to get a rapid reading of VOC concentrations directly in the field," said Mizaikoff. Georgia Institute of Technology Research News |
|||||||||||||||||||||
| Related Sensor Current Events and Sensor News Articles New Method to Measure Snow, Soil Moisture With GPS May Benefit Meteorologists, Farmers A research team led by the University of Colorado at Boulder has found a clever way to use traditional GPS satellite signals to measure snow depth as well as soil and vegetation moisture, a technique expected to benefit meteorologists, water resource managers, climate modelers and farmers. Simple test could offer cheap solution to detecting landmines Scientists have developed a simple, cheap, accurate test to find undetected landmines. Understanding mechanical properties of silicon nanowires paves way for nanodevices Silicon nanowires are attracting significant attention from the electronics industry due to the drive for ever-smaller electronic devices, from cell phones to computers. Sculptured materials allow multiple channel plasmonic sensors Sensors, communications devices and imaging equipment that use a prism and a special form of light -- a surface plasmon-polariton -- may incorporate multiple channels or redundant applications if manufacturers use sculptured thin films. NRL sensor provides critical space weather observations Launched from Vandenberg Air Force Base, Calif., aboard an United Launch Alliance Atlas V launch vehicle, Oct. 18, 2009, the Special Sensor Ultraviolet Limb Imager (SSULI) developed by NRL's Space Science Division and Spacecraft Engineering Department offers a first of its kind technique for remote sensing of the ionosphere and thermosphere from space. Magnetic mixing creates quite a stir Sandia researchers have developed a process that can mix tiny volumes of liquid, even in complicated spaces. Team led by Scripps Research and UC San Diego scientists reveals secrets of drought resistance A team of biologists in California led by researchers at The Scripps Research Institute and the University of California (UC), San Diego has solved the structure of a critical molecule that helps plants survive during droughts. Designer molecule detects tiny amounts of cyanide, then glows A small molecule designed to detect cyanide in water samples works quickly, is easy to use, and glows under ultraviolet or "black" light. Sensor biochips could aid in cancer diagnosis and treatment It is very difficult to predict whether a cancer drug will help an individual patient: only around one third of drugs will work directly in a given patient. Smallest Nanoantennas for High-speed Data Networks More than 120 years after the discovery of the electromagnetic character of radio waves by Heinrich Hertz, wireless data transmission dominates information technology. More Sensor Current Events and Sensor News Articles |
|||||||||||||||||||||
|
|||||||||||||||||||||
|
|||||||||||||||||||||