Brightsurf Science News and Current Science News Events
 
Email a Friend Send to a friend
Printer Friendly Print Team develops energy-efficient microchip

Team develops energy-efficient microchip

February 05, 2008

Could lead to longer-lasting, self-charging cellphones, more

CAMBRIDGE, Mass.-- Researchers at MIT and Texas Instruments have unveiled a new chip design for portable electronics that can be up to 10 times more energy-efficient than present technology. The design could lead to cell phones, implantable medical devices and sensors that last far longer when running from a battery.




The innovative design will be presented Feb. 5 at the International Solid-State Circuits Conference in San Francisco by Joyce Kwong, a graduate student in MIT's Department of Electrical Engineering and Computer Science (EECS).

Kwong carried out the project with MIT colleagues Anantha Chandrakasan, the Joseph F. and Nancy P. Keithley Professor of Electrical Engineering, and EECS graduate students Yogesh Ramadass and Naveen Verma. Their Texas Instruments (TI) collaborators are Markus Koesler, Korbinian Huber and Hans Moormann. The team demonstrated the ultra-low-power design techniques on TI's MSP430, a widely used microcontroller. The work was conducted at the MIT Microsystems Technology Laboratories, which Chandrakasan directs.

The key to the improvement in energy efficiency was to find ways of making the circuits on the chip work at a voltage level much lower than usual, Chandrakasan explains. While most current chips operate at around one volt, the new design works at just 0.3 volts.

Reducing the operating voltage, however, is not as simple as it might sound, because existing microchips have been optimized for many years to operate at the higher standard-voltage level. "Memory and logic circuits have to be redesigned to operate at very low power supply voltages," Chandrakasan says.

One key to the new design, he says, was to build a high-efficiency DC-to-DC converter-which reduces the voltage to the lower level-right on the same chip, reducing the number of separate components. The redesigned memory and logic, along with the DC-to-DC converter, are all integrated to realize a complete system-on-a-chip solution.

One of the biggest problems the team had to overcome was the variability that occurs in typical chip manufacturing. At lower voltage levels, variations and imperfections in the silicon chip become more problematic. "Designing the chip to minimize its vulnerability to such variations is a big part of our strategy," Chandrakasan says.

So far the new chip is a proof of concept. Commercial applications could become available "in five years, maybe even sooner, in a number of exciting areas," Chandrakasan says. For example, portable and implantable medical devices, portable communications devices and networking devices could be based on such chips, and thus have greatly increased operating times. There may also be a variety of military applications in the production of tiny, self-contained sensor networks that could be dispersed in a battlefield.

In some applications, such as implantable medical devices, the goal is to make the power requirements so low that they could be powered by "ambient energy," Chandrakasan says-using the body's own heat or movement to provide all the needed power. In addition, the technology could be suitable for body area networks or wirelessly enabled body sensor networks.

"Together, TI and MIT have pioneered many advances that lower power in electronic devices, and we are proud to be part of this revolutionary, world-class university research," said Dr. Dennis Buss, chief scientist at Texas Instruments. "These design techniques show great potential for TI future low-power integrated circuit products and applications including wireless terminals, battery-operated instrumentation, sensor networks and medical electronics."

Massachusetts Institute of Technology




More Implantable Medical Device News Articles


Implantable Medical Devices in Thailand: A Strategic Entry Report, 1999 (Strategic Planning Series)
by The Healthcare Research Group

The primary audience for this report is managers involved with the highest levels of the strategic planning process, and consultants who help their clients with this task. The user will not only benefit from the hundreds of hours that went into the methodology and its application, but also from its alternative perspective on strategic planning in Thailand.This report helps executives evaluate...

Expect consolidation in medical device industry.(Practice Trends): An article from: Skin & Allergy News
by Joyce Frieden

This digital document is an article from Skin & Allergy News, published by International Medical News Group on June 1, 2004. The length of the article is 1099 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

Current Perspectives on Implantable Devices: A Research Annual, 1989 (Current Perspectives on Implantable Devices)

U.S. Implantable and Interventional Cardiovascular Device Markets: Increase Competition Within a $1.86 Billion Industry
by Market Intelligence

Batteries for Implantable Biomedical Devices

Ce Marking for Medical Devices: A Handbook to the Medical Devices Directives : Medical Devices Directive 93/42/Eec : The Active Implantable Medical Devices Directive 90/396/Eec
by C. C. W. Schoenmakers

Routes to Successfully Selling Medical Devices and Equipment in the EC: Implantable Products (An MDIS report)
by John Matthews

The Active Implantable Medical Devices Regulations 1992 (Statutory Instruments: 1992: 3146)



ISO 14708-2:2005, Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers
by ISO/TC 150/SC 6

ISO 14708-2:2005 specifies requirements that are applicable to those active implantable medical devices intended to treat bradyarrhythmias (cardiac pacemakers). The tests that are specified in ISO 14708-2:2005 are type tests, and are to be carried out on samples of a device to show compliance. ISO 14708-2:2005 is also applicable to some non-implantable parts and accessories of the devices. The...

Active implantable medical devices (The single market)
by Great Britain

© 2008 BrightSurf.com