Science Current Events | Science News | Brightsurf.com
 
Email a Friend Send to a friend
Printer Friendly Print DES: New elements in the debate

DES: New elements in the debate

September 02, 2008

Results announced at the 2006 ESC meeting in Barcelona questioned the long-term safety of drug eluting stents (DES) and sparked intense discussion.

The dark side of this debate was an unjustified alarm when results were presented in the general press which created unnecessary anxiety among the thousands of patients who have already received stents. Since the data supporting the main meta-analysis which created this concern proved to be not scientifically sound (1), we must regret the lack of a more balanced data presentation and critical review which could have prevented needless discomfort and suffering.




The positive side of this debate has been that existing randomised trials and registries have been intensely scrutinised and plans have been made for more adequately powered trials with results applicable to the majority of patients treated for coronary artery disease.

The European Society of Cardiology, represented by a former Past-President, Professor Marten Simoons, Thoraxcentre, Rotterdam, NL, in cooperation with the European Association of Percutaneous Cardiovascular Interventions, represented by its Chairman Professor William Wijns, Aalst, Belgium, organised a Consensus Conference in Nice where data form late follow-up of trials and registries was reviewed. On September 27 and 28, 2007, key opinion leaders in clinical and interventional cardiology and representatives from industry and regulatory bodies gathered at the European Heart House with studies and registries presenting data on restenosis , re-intervention, late stent thrombosis, myocardial infarction, mortality of DES compared with bare metal stents (BMS). Results showed 2 divergent trends difficult to reconciliate. Late stent thrombosis, developing > 1 year after stent implantation, was exceedingly rare with BMS but was present in approx. 0.1-0.2% per year in the simple lesions and patients randomized in clinical trials (2) and reached percentages as high as 0.5-0.6% per year when all-comers were followed up closely in centres with high average complexity of interventions performed (3). The existing data shows this trend to be persistent for the first 3-4 years after implantation. Paradoxically, this increased rate of late thrombosis does not translate into an increase in mortality or incidence of myocardial infarction despite the fact that late thromboses are associated in more than 2/3 of cases with these catastrophic events. The most likely explanation is that the evidence that restenosis and reinterventions are not as benign as the opponents of DES indicated, with restenosis presenting as acute coronary syndromes in 20% of cases, often inducing periprocedural complications at the time of retreatment with surgery or angioplasty.

Meta-analyses of randomized trials with more than 5,000 patients followed up at 4-5 years and some of the early registries of all-comers indicated that BMS and DES have similar mortality and incidence of myocardial infarction, with a large advantage of DES on need for reinterventions (2-5). More recent registries involving a majority of complex lesions and patients that did not qualify for the classical randomized trials went further and suggested a benefit of DES in terms of late events (6,7).

We still have limited data from dedicated trials addressing the long-term safety and efficacy of DES in high-risk subgroups like diabetics, and patients with ST and non ST segment elevation MI or complex lesions (bifurcations, long lesions) but registry data and small scale studies suggest the benefit in terms of new revascularisation and late events can be greater in these high risk situations.

Existing data indicate that there are important differences between the various types of stents, with dissimilar mechanical and pharmacological properties and subsequent differences in clinical outcome. Ongoing large scale trials with second and third generation DES have been powered and have extended their follow-up long enough to support claims of reduced thrombogenicity of these devices. During the conference, there was consensus among regulatory bodies, investigators and the Industry that future randomized controlled trials pre-registration should strive to include all-comers and should be followed by large-scale all-comer registries to assess both the benefits and late complications. Initial approval might be based on assessment of restenosis (angiography, IVUS) or neointima formation and stent coverage (OCT, endothelial function studies) including one-year clinical follow up but these data should be followed by the assessment of death, MI and stent thrombosis over longer follow-up (at yearly intervals up to 3 to 5 years).

In order to define indications, cost-effectiveness analyses are essential but careful interpretation is needed when analyzing specific patient subsets derived from clinical trials which might not reflect real world clinical practice. The only regulatory body which issued a specific recommendation (the National Institute of Cost-Effectiveness, NICE from the UK) issued a statement in 2007 suggesting that DES would be cost-effective in the majority of patients undergoing percutaneous coronary intervention at a price premium around €400 above the price of comparable BMS. Despite this remaining a controversial issue, it is interesting to note that the price differential between DES and BMS has already fallen below this threshold in almost all European countries.

European Society of Cardiology



Related Drug Eluting Stents Current Events and Drug Eluting Stents News Articles
Modified herpes virus keeps arteries 'free-flowing' following procedures
A genetically engineered herpes simplex virus, primarily known for causing cold sores, may help keep arteries "free-flowing" in the weeks following angioplasty or stent placement for patients, according to research published early in the online edition of PNAS (Proceedings of the National Academy of Sciences of the United States of America).

Drug-eluting stents may cause allergic reactions
Drug-eluting stents have greatly reduced the risk of repeat blockage of heart arteries, but researchers from Northwestern Memorial Hospital have found that in some patients, the stents can cause allergic reactions that can have serious consequences.

ESC Congress 2003: ESC Guidelines for Percutaneous Coronary Interventions (PCI)
IMPORTANT: This press release accompanies a presentation given at the ESC Congress 2003. Written by the investigator himself/herself, this press release does not necessarily reflect the opinion of the European Society of Cardiology Background: The non-surgical treatment of severely narrowed coronary arteries (stenosis) has grown tremendously over the last years with now over 1 million procedures world-wide. These procedures are performed through a little skin incision in the groin („percutaneous") to avoid open heart surgery. In contrast to the early days of PCI, where only „plain" balloons were available, there is an increasing number of various additional devices, met
More Drug Eluting Stents Current Events and Drug Eluting Stents News Articles
IMPROVED JANUS FLEX DRUG ELUTING STENT LAUNCHED IN EUROPE. : An article from: Biotech Equipment Update

This digital document is an article from Biotech Equipment Update, published by Thomson Gale on April 1, 2006. The length of the article is 498 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation DetailsTitle:...



Handbook of Drug-Eluting Stents
by Patrick W. Serruys, Anthony H. Gershlick

Over the past few years, the focus in interventional cardiology research has centered on reducing restenosis with the use of antiproliferative pharmacological agents. The use of these drugs, hitherto, has failed, most probably because of low active drug levels at the target site. This problem led to the development of local drug delivery using stents, since they can serve as a reservoir for local...

MEDIVAS/ESTRACURE SIGN PACT FOR DRUG ELUTING STENT.: An article from: Biotech Equipment Update

This digital document is an article from Biotech Equipment Update, published by Worldwide Videotex on September 1, 2005. The length of the article is 488 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

Drug-eluting stents avert small-vessel restenosis.(Cardiovascular Medicine): An article from: Internal Medicine News
by Bruce Jancin

This digital document is an article from Internal Medicine News, published by International Medical News Group on June 15, 2004. The length of the article is 801 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

Drug-eluting stents meet standard of cost effectiveness.(Cardiovascular Medicine): An article from: Internal Medicine News
by Mitchel L. Zoler

This digital document is an article from Internal Medicine News, published by International Medical News Group on March 15, 2005. The length of the article is 522 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

Late thrombosis haunts drug-eluting stents.(Cardiovascular Medicine): An article from: Family Practice News
by Mitchel L. Zoler

This digital document is an article from Family Practice News, published by International Medical News Group on March 15, 2005. The length of the article is 1184 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

MINIMALLY INVASIVE SURGERY DRIVES DRUG ELUTING STENT MARKET.: An article from: Biotech Equipment Update

This digital document is an article from Biotech Equipment Update, published by Thomson Gale on March 1, 2006. The length of the article is 942 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation DetailsTitle:...

Pro & Con: is it too early to jump on the bandwagon for drug-eluting stents?: An article from: Family Practice News

This digital document is an article from Family Practice News, published by International Medical News Group on December 1, 2002. The length of the article is 885 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

Conditional OK for drug-eluting stent. (FDA Panel).: An article from: Family Practice News
by Deeanna Franklin

This digital document is an article from Family Practice News, published by International Medical News Group on December 1, 2002. The length of the article is 726 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

Drug-eluting stents meet cost-effectiveness standards.(Cardiovascular Medicine): An article from: Family Practice News
by Mitchel L. Zoler

This digital document is an article from Family Practice News, published by International Medical News Group on March 15, 2005. The length of the article is 548 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.Citation...

© 2008 BrightSurf.com