Drug-eluting stents found safe, superior to bare metal stentsMarch 30, 2009DURHAM, NC - Drug-eluting stents were safe and superior to bare metal stents in preventing death and heart attacks among 262,700 "real-world" patients enrolled in a nationwide registry of cardiovascular disease, according to researchers from Duke University Medical Center. The findings were presented today at the i2Summit at the American College of Cardiology's 58th Annual Scientific Session. They also appear online in the Journal of the American College of Cardiology. The study is the largest of its kind to date and may end years of controversy over the safety of the devices. "We hope these findings will finally lay to rest any doubt about the safety of drug-eluting stents," says Pamela Douglas, M.D., a cardiologist and member of the Duke Heart Center at Duke University Medical Center and the lead author of the study. "Our results clearly show that drug-eluting stents are indeed safe." Stents are small tubes that can prop open blocked coronary arteries. The earliest versions were made of bare metal mesh, but later models were designed to release a medication that could suppress restenosis, or the growth of new tissue that could cause the artery to clog up again. Physicians have been debating their relative merit for years. After initially proving more effective than bare metal stents in preventing restenosis, drug-eluting stents suffered a setback when recent clinical trials found them associated with higher long-term death rates. Those findings led to warnings from the Food and Drug Administration and confusion over which option is better. Douglas and colleagues followed patients over age 65 enrolled in the National Cardiovascular Data Registry who had received stents from 2004 through 2006. Most of the patients had received a drug-eluting stent; only 17 percent were implanted with the bare metal variety. Investigators matched the patients' data with their Medicare claims and followed them for two and one-half years, measuring rates of death, heart attack, stroke, bleeding and the need for additional artery-opening procedures. They found that over the 30-month period, patients in the drug-eluting stent group had a 25 percent reduction in death and 24 percent reduction in heart attacks, when compared with those who received bare metal stents, but no significant difference in the incidence of stroke, major bleeding or need for additional artery-opening procedures. Douglas says the study is important on several fronts. "First, the data show that over a two and one-half year follow up, drug-eluting stents are safe among patients in a real-world, highly variable environment. Patients who enroll in clinical trials are generally younger, healthier and on fewer medications that the population at large, and that means that clinical trials can generate findings that may not hold up in larger, more variable, community populations," says Douglas. "In addition, we believe this is the first time that anyone has been able to link so much clinical data with Medicare claims. What that essentially has given us is an excellent model for future post-marketing evaluation," says Douglas, who adds that such studies may be particularly attractive to payers, health care policy makers and anyone interested in health care reform who needs real-world data, as opposed to that generated by clinical trials. Duke University Medical Center |
|||||||||||||||||||||
| Related Drug-eluting Stents Current Events and Drug-eluting Stents News Articles Higher carotid arterial stenting rates associated with poorer clinical outcomes Among eligible Medicare beneficiaries, increased use of carotid arterial stenting (CAS) procedures to treat carotid stenosis-the narrowing of the carotid artery-is associated with higher rates of mortality and adverse clinical outcomes, including heart attack and stroke, according to researchers from the University of Pennsylvania School of Medicine. Drug-eluting stents better than bare-metal stents for heart attack patients Late-breaking data from the landmark HORIZONS-AMI clinical trial, presented at the 21st annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, demonstrated that after two years, in heart attack patients, the use of a drug-eluting stent (paclitaxel) was safer and more effective than a bare-metal stent; and that the administration of the anticoagulant medication bivalirudin enhanced safety and efficacy compared to the use of heparin + GPIIb/IIIa inhibitors. SPIRIT IV trial shows everolimus stent sets new standard for event-free survival Late-breaking data from SPIRIT IV, a large-scale multi-center study of nearly 4,000 patients in the U.S., shows that an everolimus-eluting stent demonstrated enhanced safety and efficacy in the treatment of de novo native coronary artery lesions when compared to a paclitaxel-eluting stent, and showed that "low late loss" may be achieved with drug-eluting stents without sacrificing safety. Drug-eluting stents safe, effective for treatment of chronic total occlusions A multicenter study in Asia found drug-eluting stents effective with a low rate of acute complications in patients with chronic total occlusions (CTOs) undergoing PCI. Results of the study will be presented at the 21st annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation (CRF). Researchers find drug-eluting stents safe, effective for PCI in diabetics Results of a multicenter study in Asia, demonstrating that drug-eluting stents are effective with a low rate of complications in diabetic patients, will be presented at the 21st annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation (CRF). Fast release of data leads to rapid changes in clinical practice for drug-eluting stents E-mail, search engines, smart phones and other new technologies that can disseminate new medical information quickly led to an almost immediate change in clinical practice for drug-eluting stents, according to a study reported in Circulation: Cardiovascular Quality and Outcomes. Analysis of drug-eluting stents data demonstrates safety, efficacy in on-and-off-label use The Cardiovascular Research Foundation (CRF) announced that results of the largest meta-analysis to date comparing mortality rates for drug-eluting stents (DES) versus bare metal stents (BMS) were published online June 15 in the journal Circulation. NEJM study finds drug-eluting stents more effective than bare-metal stents in heart attack patients NewYork-Presbyterian Hospital and Columbia University Medical Center, together with the Cardiovascular Research Foundation (CRF), announced that its landmark study comparing the safety and efficacy of drug-eluting stents and bare-metal stents was published in the May 7 New England Journal of Medicine. Drug-eluting stents prove more effective, equally as safe as bare-metal stents The Cardiovascular Research Foundation (CRF) announced that its landmark study comparing the safety and efficacy of drug-eluting stents and bare-metal stents was published today in The New England Journal of Medicine. Promising 3-year data: Saving limbs with drug-eluting stents Attempts to treat critical limb ischemia in peripheral arterial disease (PAD) patients with below-the-knee angioplasty are still thwarted by restenosis (the re-narrowing of the artery at the site of angioplasty or stenting), the need for repeat treatments and the continued progression of atherosclerotic disease, leading to tissue death (gangrene) and amputation. More Drug-eluting Stents Current Events and Drug-eluting Stents News Articles |
|||||||||||||||||||||
|
|||||||||||||||||||||
|
|||||||||||||||||||||