New lab-on-a-chip measures mechanics of bacteria colonies

July 01, 2009

ANN ARBOR, Mich.---Researchers at the University of Michigan have devised a microscale tool to help them understand the mechanical behavior of biofilms, slimy colonies of bacteria involved in most human infectious diseases.

Most bacteria in nature take the form of biofilms. Bacteria are single-celled organisms, but they rarely live alone, said John Younger, associate chair for research in the Department of Emergency Medicine at the U-M Health System. Younger is a co-author of a paper about the research that will be the cover story of the July 7 edition of Langmuir.




The new tool is a microfluidic device, also known as a "lab-on-a-chip." Representing a new application of microfluidics, the device measures biofilms' resistance to pressure. Biofilms experience various kinds of pressure in nature and in the body as they squeeze through capillaries and adhere to the surfaces of medical devices, for example.

"If you want to understand biofilms and their life cycle, you need to consider their genetics, but also their mechanical properties. You need to think of biofilms as materials that respond to forces, because how they live in the environment depends on that response," said Mike Solomon, associate professor of chemical engineering and macromolecular science and engineering, who is senior author of the paper.

Mechanical forces are at play when our bodies defend against these bacterial colonies as well, Younger says.

"We think a lot of host defense boils down to doing some kind of physical work on these materials, from commonplace events like hand-washing and coughing to more mysterious processes like removing them out of the bloodstream during a serious infection," he said. "You can study gene expression patterns as much as you want, but until you know when the materials will bend or break, you don't really know what the immune system has to do from a physical perspective to fight this opponent."

Researchers haven't studied these properties yet because there hasn't been a good way to examine biofilms at the appropriate scale.

The U-M microfluidic device provides the right scale. The channel-etched chip, made from a flexible polymer, allows researchers to study minute samples of between 50 and 500 bacterial cells that form biofilms of 10-50 microns in size. A micron is one-millionth of a meter. A human hair is about 100 microns wide.

Such small samples behave in the device as they do in the body. Tools that require larger samples don't always give an accurate picture of how a particular substance behaves on the smallest scales.

The researchers found that the biofilms they studied had a greater elasticity than previous methods had measured. They also discovered a "strain hardening response," which means that the more pressure they applied to the biofilms, the more resistance the materials put forth.

If doctors and engineers can gain a greater understanding of how biofilms behave, they could perhaps design medical equipment that is more difficult for the bacteria to adhere to, Younger said.

The experiments were performed on colonies of Staphylococcus epidermidis and Klebsiella pneumoniae, which are known to cause infections in hospitals.

The new microfluidic device could also be used to measure the resistance of various other soft-solid materials in the consumer products, food science, biomaterials and pharmaceutical fields.

University of Michigan



Related Microfluidic Device Current Events and Microfluidic Device News Articles Microfluidic Device Current Events and Microfluidic Device News RSS Microfluidic Device Current Events and Microfluidic Device News RSS
Novel NIST connector uses magnets for leak-free microfluidic devices
Like other users of microfluidic systems, National Institute of Standards and Technology (NIST) researcher Javier Atencia was faced with an annoying engineering problem: how to simply, reliably and most of all, tightly, connect his tiny devices to the external pumps and reservoirs delivering liquids into the system.

Tiny injector to speed development of new, safer, cheaper drugs
It's no bigger than a stamp packet but it has the potential to allow rapid development of a new generation of drugs and genetic engineering organisms, and to better control in-vitro fertilization.

New nanochemistry technique encases single molecules in microdroplets
Inventing a useful new tool for creating chemical reactions between single molecules, scientists at the National Institute of Standards and Technology (NIST) have employed microfluidics-the manipulation of fluids at the microscopic scale-to make microdroplets that contain single molecules of interest.

NIST calculations may improve temperature measures for microfluidics
If you wanted to know if your child had a fever or be certain that the roast in the oven was thoroughly cooked, you would, of course, use a thermometer that you trusted to give accurate readings at any temperature within its range.

Music is the engine of new U-M lab-on-a-chip device
Music, rather than electromechanical valves, can drive experimental samples through a lab-on-a-chip in a new system developed at the University of Michigan. This development could significantly simplify the process of conducting experiments in microfluidic devices.

Separating the good from the bad
Scientists at MIT and Brown University studying how marine bacteria move recently discovered that a sharp variation in water current segregates right-handed bacteria from their left-handed brethren, impelling the microbes in opposite directions.

MIT paves way to 'artificial nose'
MIT biological engineers have found a way to mass-produce smell receptors in the laboratory, an advance that paves the way for "artificial noses" to be created and used in a variety of settings.

Make your own microfluidic device with new kit from U-M
A type of device called a "lab-on-a-chip" could bring a new generation of instant home tests for illnesses, food contaminants and toxic gases. But today these portable, efficient tools are often stuck in the lab themselves. Specifically, in the labs of researchers who know how to make them from scratch.

Automated microfluidic device reduces time to screen small organisms for genetic studies
Genetic studies on small organisms such as worms and flies can now be done more quickly using a new microfluidic device developed by engineers at the Georgia Institute of Technology.

MIT particles pave way for new bedside diagnostics
MIT researchers have created an inexpensive method to screen for millions of different biomolecules (DNA, proteins, etc.) in a single sample-a technology that could make possible the development of low-cost clinical bedside diagnostics.
More Microfluidic Device Current Events and Microfluidic Device News Articles
Optofluidics: Fundamentals, Devices, and Applications (Biophotonics)

Optofluidics: Fundamentals, Devices, and Applications (Biophotonics)
by Yeshaiahu Fainman (Author), Luke Lee (Author), Demetri Psaltis (Author), Changhuei Yang (Author)

Cutting-Edge Optofluidics Theories, Techniques, and Practices

Add novel functionalities to your optical design projects by incorporating state-of-the-art microfluidic technologies and tools. Co-written by industry experts, Optofluidics: Fundamentals, Devices, and Applications covers the latest functional integration of optical devices and microfluidics, as well as automation techniques. 

This authoritative guide explains how to fabricate optical lab-on-a-chip devices, synthesize photonic crystals, develop solid and liquid core waveguides, use fluidic self-assembly methods, and accomplish direct microfabrication in solutions. The book includes details on developing biological sensors and arrays, handling maskless lithography, designing high-Q cavities, and working with...

Rapid discrimination of single-nucleotide mismatches using a microfluidic device with monolayered beads [An article from: Analytica Chimica Acta]

Rapid discrimination of single-nucleotide mismatches using a microfluidic device with monolayered beads [An article from: Analytica Chimica Acta]
by J.K.K. Ng (Author), H. Feng (Author), W.T. Liu (Author)

This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2007. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.

Description:
A microfluidic device incorporating monolayered beads is developed for the discrimination of single-nucleotide mismatches, based on the differential dissociation kinetics between perfect match (PM) and mismatched (MM) duplexes. The monolayered beads are used as solid support for the immobilization of oligonucleotide probes containing a single-base variation. Target oligonucleotides hybridize to the probes, forming either PM duplexes or MM duplexes containing a single mismatch. Optimization studies show that PM...

  Real-time monitoring of injection molding for microfluidic devices using ultrasound.: An article from: Polymer Engineering and Science
by Y. Ono (Author), C.-K. Jen (Author), C.-C. Cheng (Author), M. Kobayashi (Author)

This digital document is an article from Polymer Engineering and Science, published by Society of Plastics Engineers, Inc. on April 1, 2005. The length of the article is 4015 words. The page length shown above is based on a typical 300-word page. The article is delivered in HTML format and is available in your Amazon.com Digital Locker immediately after purchase. You can view it with any web browser.

From the author: Real-time process monitoring of the fabrication process of microfluidic devices using a polymer injection molding machine was carried out using miniature ultrasonic probes. A thick piezoelectric lead-zirconate-titanate film as an ultrasonic transducer (UT) was fabricated onto one end of a 4-mm diameter and 12-mm long steel buffer rods using a sol gel spray technique....

Continuous flow microfluidic device for cell separation, cell lysis and DNA purification [An article from: Analytica Chimica Acta]

Continuous flow microfluidic device for cell separation, cell lysis and DNA purification [An article from: Analytica Chimica Acta]
by X. Chen (Author), D. Cui (Author), C. Liu (Author), H. Li (Author), J. Chen (Author)

This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2007. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.

Description:
A novel integrated microfluidic device that consisted of microfilter, micromixer, micropillar array, microweir, microchannel, microchamber, and porous matrix was developed to perform sample pre-treatment of whole blood. Cell separation, cell lysis and DNA purification were performed in this miniaturized device during a continuous flow process. Crossflow filtration was proposed to separate blood cells, which could successfully avoid clogging or jamming. After blood cells were lyzed in guanidine buffer, genomic...

  Microfluidic Devices in Nanotechnology: Current Status and a Future Perspective
by Challa S. S. R. Kumar (Author)

Nanotechnology, especially microfabrication, has been affecting every facet of traditional scientific disciplines. The first book on the application of microfluidic reactors in nanotechnology, Microfluidic Devices in Nanotechnology provides the fundamental aspects and potential applications of microfluidic devices, the physics of microfluids, specific methods of chemical synthesis of nanomaterials, and more. As the first book to discuss the unique properties and capabilities of these nanomaterials in the miniaturization of devices, this text serves as a one-stop resource for nanoscientists interested in microdevices.

Microfluidic Devices and Systems: Proceedings of Spir 21-22 September 1998 Santa Clara, California (Spie Proceedings Series Volume 3515)

Microfluidic Devices and Systems: Proceedings of Spir 21-22 September 1998 Santa Clara, California (Spie Proceedings Series Volume 3515)
by A. Bruno Frazier (Editor), Chong Hyuk Ahn (Editor)

This work provides a discussion of microfluidic devices and systems. It contains papers which address: pumps and valves; micro total analysis system; microfluidic systems; and microfluidic system fabrication.

Microbial detection in microfluidic devices through dual staining of quantum dots-labeled immunoassay and RNA hybridization [An article from: Analytica Chimica Acta]

Microbial detection in microfluidic devices through dual staining of quantum dots-labeled immunoassay and RNA hybridization [An article from: Analytica Chimica Acta]
by Q. Zhang (Author), L. Zhu (Author), H. Feng (Author), S. Ang (Author), F.S. Chau (Author), Liu (Author)

This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2006. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.

Description:
This paper reported the development of a microfludic device for the rapid detection of viable and nonviable microbial cells through dual labeling by fluorescent in situ hybridization (FISH) and quantum dots (QDs)-labeled immunofluorescent assay (IFA). The coin sized device consists of a microchannel and filtering pillars (gap=1-2@mm) and was demonstrated to effectively trap and concentrate microbial cells (i.e. Giardia lamblia). After sample injection, FISH probe solution and QDs-labeled antibody solution were...

The enhanced diffusional mixing for latex immunoagglutination assay in a microfluidic device [An article from: Analytica Chimica Acta]

The enhanced diffusional mixing for latex immunoagglutination assay in a microfluidic device [An article from: Analytica Chimica Acta]
by J.H. Han (Author), K.S. Kim (Author), J.Y. Yoon (Author)

This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2007. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.

Description:
Latex immunoagglutination assay in a microfluidic device is expected to be even easier than its large-sized, commercialized counterpart. However, such demonstration has had a limited success due to the difficulties in mixing in a microfluidic device, especially for the microparticles used in latex immunoagglutination assay. The primary goal of this work is to improve diffusional mixing towards the successful latex immunoagglutination in a microfluidic devices without any non-specific binding. To this end, SDS...

  Microfluidic Devices in Nanotechnology Part II
by Challa S. Kumar (Author)

This is the first book to discuss the developments in microfluidics coupled with nanotechnology. This approach is a revolutionary way for growing numbers of investigations to replace, in the future, conventional synthesis of nanomaterials and nanomaterials-based analytical methods by lab-on-a-chip systems combining micro fluidic devices with nanotechnology. Exciting applications range from chemistry, biology, molecular and cell biology, neuroscience, catalysis and nanomaterial’s synthesis.. With reviews by world-recognized microflluidic and nanotechnology experts, this authoritative work provides strong scaffolding for futuristic applications utilizing synergy from two powerful scientific elements.

Integrated microfluidic devices [An article from: Analytica Chimica Acta]

Integrated microfluidic devices [An article from: Analytica Chimica Acta]
by D. Erickson (Author), D. Li (Author)

This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2004. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.

Description:
''With the fundamentals of microscale flow and species transport well developed, the recent trend in microfluidics has been to work towards the development of integrated devices which incorporate multiple fluidic, electronic and mechanical components or chemical processes onto a single chip sized substrate. Along with this has been a major push towards portability and therefore a decreased reliance on external infrastructure (such as detection sensors, heaters or voltage sources).'' In this review we provide an...

© 2009 BrightSurf.com