Science Current Events | Science News | Brightsurf.com
 
Email a Friend Send to a friend
Printer Friendly Print Concrete columns with internal bars made of glass fibers can make a building sturdier

Concrete columns with internal bars made of glass fibers can make a building sturdier

July 15, 2009

The University of Miami, through its NSF Industry/University Cooperative Research Center RB2C performed the first-ever tests of full-scale concrete columns internally reinforced with glass fiber reinforced polymer bars

CORAL GABLES, FL - Conventional means of internal reinforcement for concrete member in buildings involve steel bars. Yet for structures that function in harsh environments like coastal regions, or for structures that support sensitive equipment, such as magnetic resonance imaging units; the use of fiber reinforced polymer (FRP) is emerging as a valuable option, due to its natural resistance to corrosion, its high strength, light weight, transparency to electrical and magnetic fields and ease of manufacturing and installment.

However, little has been done to study the performance of concrete columns reinforced with FRP bars. Currently the American Concrete Institute, a nonprofit technical and educational society and one of the world's leading authorities on concrete technology, does not address the use of FRP bars for reinforcement in columns, but welcomes additional relevant research and experimental evidence.




Full-scale experiments are critical to validate the technology, and to produce compelling evidence that underpins rational design methodologies. To address this need, the National Science Foundation (NSF) Industry/University Cooperative Research Center "Repair of Buildings and Bridges with Composites" (RB2C) at the University of Miami (UM) examined the behavior of concrete (RC) columns internally reinforced with glass FRP (GFRP) bars on full-scale specimens for the first time ever.

The new study demonstrates that the behavior of GFRP-RC columns was very similar to that of the conventional steel counterpart. The results of this project will be presented by Antonio De Luca, graduate student at the University of Miami College of Engineering, during the 9th International Symposium on Fiber Reinforced Polymer Reinforcement for Concrete Structures, in Sydney Australia, on July 13-15.

"The outcomes of our study provide a compelling case to modify existing design guidelines and allow for limited use of GFRP bars in columns, particularly when corrosion resistance or electromagnetic transparency is sought," De Luca said.

Other important findings of this project include:

* The GFRP vertical bars are not detrimental for the concrete column performance.
* The contribution of the GFRP to the column capacity is very small, if the amount of longitudinal reinforcement is used. Therefore, the presence of the GFRP bars can be neglected in the computation of the ultimate column capacity.
* Difference in manufacturer of the GFRP bars does not affect the performance when bars are of the same quality.
* Use of GFRP bars as compression reinforcement may be allowed when design is for vertical loads only.

The next stage of the study is meant to demonstrate that specimen scale does not affect GFRP-RC column specimen performance; and to investigate the behavior of GFRP-RC column specimens subjected to compressive load applied with a small eccentricity.

University of Miami




More Reinforcement Concrete Current Events and Reinforcement Concrete News Articles
Galvanized Steel Reinforcement in Concrete

Galvanized Steel Reinforcement in Concrete
by Stephen Yeomans (Author)

Reinforced concrete is one of the most widely used modern materials of construction. It is comparatively cheap, readily available, and suitable for a variety of building and construction applications.

This reference provides a detailed resource covering all aspects of this important material. Both servicability and durability aspects are well covered, with all the information needed maximise the life of buildings constructed from it.

Containing an up-to-date and comprehensive collection of technical information and data from world renound authors, it will be a valuable source of reference for academics, researchers, students and professionals alike.

*Provides information vital to prolong the life of buildings constructed from...

MK-4096-1 CORE DRILL 20 AMP, SLIP CLUTCH, COMBO VAC OR ANCHOR BASE - INCLUDES A 2, 3, 4, 5, AND 6" WET PREMIUM TURBO CORE BIT FOR CURED CONCRETE WITH HEAVY STEEL REINFORCEMENT

MK-4096-1 CORE DRILL 20 AMP, SLIP CLUTCH, COMBO VAC OR ANCHOR BASE - INCLUDES A 2, 3, 4, 5, AND 6" WET PREMIUM TURBO CORE BIT FOR CURED CONCRETE WITH HEAVY STEEL REINFORCEMENT
by MK

This package includes: 1. MILWAUKEE 20 AMP MOTOR, SLIP CLUTCH, 2-SPEED (450 or 900 RPM) 2. Tilt Stand Tilts up to 45 degree 2-1/2" zinc-plated steel column with ceiling jack Lightweight cast-aluminum base with built-in wheels Positive anchoring for vertical & horizontal drilling One-piece removable slide handle easily negotiates close to walls and columns 3. Vacuum Pump The MANTA III Core Drill Rig is built to stand up to the rigors of high performance product drilling. The Steel column is precision blanched ground for accurate drilling. The hardened rack and pinion gear action combined with precise head play adjustment assures straight drill holes up to 10 inches in diameter. MANTA III Core Drill Rigs Features: Dual plug control box/amp meter A one-piece slide handle easily...

Fiber-Reinforced Polymer: Reinforcement for Concrete Structures

Fiber-Reinforced Polymer: Reinforcement for Concrete Structures
by Kiang Hwee Tan (Editor)

Fibre-reinforced polymer (FRP) reinforcement has been used in construction as either internal or external reinforcement for concrete structures in the past decade. This book provides the latest research findings related to the development, design and application of FRP reinforcement in new construction and rehabilitation works. The topics include FRP properties and bond behaviour, externally bonded reinforcement for flexure, shear and confinement, FRP structural shapes, durability, member behaviour under sustained loads, fatigue loads and blast loads, prestressed FRP tendons, structural strengthening applications, case studies, and codes and standards.

Minimum Reinforcement in Concrete Members, Volume 24 (European Structural Integrity Society)

Minimum Reinforcement in Concrete Members, Volume 24 (European Structural Integrity Society)
by A. Carpinteri (Author)

The ESIS-Technical Committee 9 on Concrete was established in 1990 and has met seven times. A proposal was put to European and extra-European laboratories entitled "Scale effects and transitional failure phenomena of reinforced concrete beams in flexure" which lead to several positive responses.

The central topic discussed by the committee was that of the minimum reinforcement in concrete members. The minimum amount of reinforcement is defined as that for which "peak load at first concrete cracking" and "ultimate load after steel yielding" are equal. In this way, any brittle behaviour is avoided as well as any localized failure, if the member is not over-reinforced. In other words, there is a reinforcement percentage range, depending on the size-scale, within which the plastic limit...

  Developments in the Formulation and Reinforcement of Concrete
by S. Mindess (Editor)

Developments in the formulation and reinforcement of concrete are of great topical interest to the construction industry worldwide, with applications in high-rise, offshore, nuclear and bridge structures, and in pre-cast concrete. This authoritative book addresses the current lack of information on the latest developments in the formulation and reinforcement of concrete in one source. The book discusses the latest types of reinforced concrete and reinforcement and includes chapters on hot weather concreting, cold weather concreting and the use of recycled materials in concrete. It presents current research from leading innovators in the field.

  Contractors Equipment, Concrete Reinforcing, Construction Equipment, Earth and Rock Machinery, Bars and Mesh for Concrete Reinforcement
b



ISO 3766:2003, Construction drawings - Simplified representation of concrete reinforcement

ISO 3766:2003, Construction drawings - Simplified representation of concrete reinforcement
by ISO/TC 10/SC 8 (Author)

ISO 3766:2003 specifies the simplified representation and the characterization of reinforcement in reinforced and in prestressed concrete for use in construction drawings. It also establishes a system for the scheduling of reinforced bars, comprising a method for specifying dimensions, a coding system for bar shapes, a schedule of preferred shapes and shape and bending schedules.

Concrete Reinforcement Corrosion: ICE Design and Practice (Ice Design and Practice Guide)

Concrete Reinforcement Corrosion: ICE Design and Practice (Ice Design and Practice Guide)
by Thomas Telford Ltd. (Author)

Reinforcement corrosion is the most important cause of deterioration in reinforced concrete structures. This guide will assist readers to identify it, understand its causes, assess its implications and come up with solutions. Drawing on author Peter Pullar-Strecker's 15 year of hands-on experience with all kinds of structures worldwide, the guide explains basic mechanisms and techniques in a straightforward manner. It includes enough practical details to enable non-specialist investigators to carry out at least some initial investigation themselves and considers the problems of detailed investigations in a way which even the most experienced consultants and their clients will find helpful. The guide compares the different repair methods which have become established during recent years...

  Triangle Mesh Concrete Reinforcement Engineers' Handbook
by American Steel & Wire Co (Author)

Hndbook and Catalogue

ISO 6935-3:1992, Steel for the reinforcement of concrete - Part 3: Welded fabric

ISO 6935-3:1992, Steel for the reinforcement of concrete - Part 3: Welded fabric
by ISO TC 17/SC 16 (Author)

Specifies technical requirements and test methods (form and dimensions, chemical composition, mechanical properties, designation, marking, certification and inspection, verification of conformity) for factory made sheets or rolls of welded fabric, manufactured from steel wires or bars with diameters from 4 mm to 16 mm. This title may contain less than 24 pages of technical content.

© 2009 BrightSurf.com