Replacing hydrogen in fluorescent dyes improves detection ability, stability and shelf lifeJuly 21, 2010By swapping out one specific hydrogen atom for an isotope twice as heavy, researchers have increased the shelf life and detection ability of fluorescent probes that are essential to studying a variety of inflammatory diseases, including cancer and atherosclerosis. The probes detect and measure reactive oxygen species, which play an important role in disease processes. "By replacing a hydrogen atom with a deuterium atom during the synthesis of several fluorescent probes, we increased the stability and shelf life of the dyes, and also improved their ability to detect smaller concentrations of reactive oxygen species," said Niren Murthy, associate professor in the Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech and Emory University. Deuterium is an isotope of hydrogen that has a single proton and single neutron in its nucleus. Its atomic weight is therefore twice that of the much more common hydrogen atom, which lacks a neutron. When Murthy and Coulter Department postdoctoral fellow Kousik Kundu designed and synthesized various fluorescent probes with deuterium instead of hydrogen, the dyes were not as susceptible to spontaneous degradation by air and light as their hydrogen counterparts, which made them significantly more accurate at detecting reactive oxygen species in cells and animals. The researchers studied probes that included dihydroethidium (DHE) -- the current "gold standard" for imaging reactive oxygen species -- and hydrocyanines. Details of the research were published in the early view of the journal Angewandte Chemie International on July 20. The work was sponsored by the National Institutes of Health and the National Science Foundation. The study showed that while the standard fluorescent probe DHE was 60 percent oxidized by air and light after 10 days in storage, its deuterium counterpart was only 20 percent oxidized during that same time. These findings could have significant implications for companies that produce fluorescent probes and other compounds, according to Murthy, because commercializing and shipping the modified probes will be easier. Another advantage for scientists using deuterium-containing fluorescent probes is that after reacting with reactive oxygen species, the probes produce the same fluorescent dye that their hydrogen counterparts produce. "This is important from a practical standpoint because scientists have developed protocols with DHE and other fluorescent probes that they will be able to continue using by simply substituting the more stable and accurate deuterated version into the assay," explained Murthy. Fluorescent probes detect reactive oxygen species by undergoing a chemical process called amine oxidation. The mechanism of amine oxidation for reactions involving reactive oxygen species differs significantly from reactions involving air and light. In addition, reactions with deuterium-containing probes occur at a much slower rate because deuterium is a heavier atom. Murthy and Kundu decided to use these mechanistic and kinetic differences to selectively slow the oxidation of the fluorescent probes by air and light while maintaining their reactivity with cellular reactive oxygen species. To test the selective suppression of oxidation, the researchers examined the kinetic isotope effect -- a value that measures the ratio of the rate of a chemical reaction with hydrogen compared to the same reaction with deuterium to air and radical oxidation. They investigated the ability of the deuterium-containing probes to compete with a common enzyme for superoxide -- a reactive oxygen species that is a form of molecular oxygen with one extra electron. The researchers found that the probes' oxidation mechanism with superoxide was different than for spontaneous oxidation because the two reactions exhibited different values for the kinetic isotope effect. Kinetic isotope effect values for spontaneous oxidation ranged from 3.7-4.7, whereas values for superoxide oxidation were between 2.5-2.8 for many different types of deuterium-containing fluorescent dyes, including DHE. "This was the key experiment that demonstrated that there was a much larger difference in the way the hydrogen and deuterium compounds reacted to spontaneous oxidation than how they dealt with oxidation by a reactive oxygen species," explained Murthy. Murthy's collaborators W. Robert Taylor and Sarah Knight tested the ability of both types of dyes to detect reactive oxygen species inside cells. Since the deuterium-containing probes were less affected by air and light and background fluorescence was suppressed, the researchers found that the dyes more accurately detected small amounts of reactive oxygen species. Knight is an Emory University postdoctoral fellow and Taylor is a professor in the Coulter Department, the director of Emory's Division of Cardiology, and a member of the Atlanta VA Medical Center's Division of Cardiology. Following the cellular experiments, Knight and Coulter Department postdoctoral fellow Seungjun Lee investigated whether the kinetic isotope effect would similarly improve the ability of H-Cy7 -- a hydrocyanine dye developed by Murthy -- to detect radical oxidants in vivo. In experiments, the deuterium-containing version of Cy7 generated a 10-fold difference in fluorescence intensity versus control probes compared to only a five-fold difference for the hydrogen probe. "This new process of replacing hydrogen with deuterium is potentially valuable because the positive results are universal among many different types and classes of probes," explained Murthy. "All of the modified probes generated less background fluorescence, while maintaining high reactivity with reactive oxygen species and generating similar levels of fluorescence in cells and animals stimulated to produce them." Murthy indicated that although the kinetic isotope effect had been used to improve drug stability, it has never been used to improve probe development. "Based on our results, we anticipate numerous applications of deuterated radical oxidant probes in biology and an increased application of the kinetic isotope effect in biological probe development," added Murthy. Georgia Institute of Technology Research News |
|||||||||||||||||||||
| Related Fluorescent Dyes Current Events and Fluorescent Dyes News Articles Researchers Turn Up Brightness on Fluorescent Probes Researchers from Carnegie Mellon University's Molecular Biosensor and Imaging Center (MBIC) are turning up the brightness on a group of fluorescent probes called fluoromodules that are used to monitor biological activities of individual proteins in real-time. Off-the-shelf cancer detection Using an off-the-shelf digital camera, Rice University biomedical engineers and researchers from the University of Texas M.D. Anderson Cancer Center have created an inexpensive device that is powerful enough to let doctors easily distinguish cancerous cells from healthy cells simply by viewing the LCD monitor on the back of the camera. Ultrasensitive imaging method uses gold-silver 'nanocages' New research findings suggest that an experimental ultrasensitive medical imaging technique that uses a pulsed laser and tiny metallic "nanocages" might enable both the early detection and treatment of disease. How dangerous are air pollutants really? Through this system, it will be possible for the first time ever to channel substances from the air, under precisely controlled conditions, through the lung cells or skin cells, and simultaneously observe the reactions of these cells under the microscope. Oscillations at odds in the heart Researchers in Germany show that a classical biological oscillator, the glycolytic oscillator, may increase damage to the heart during acute loss of oxygen (anoxia), and as may occur during ischemia. Researchers develop innovative imaging system to study sudden cardiac arrest A research team at Vanderbilt University has developed an innovative optical system to simultaneously image electrical activity and metabolic properties in the same region of a heart, to study the complex mechanisms that lead to sudden cardiac arrest. NIST calculations may improve temperature measures for microfluidics If you wanted to know if your child had a fever or be certain that the roast in the oven was thoroughly cooked, you would, of course, use a thermometer that you trusted to give accurate readings at any temperature within its range. New DNA Test Uses Nanotechnology to Find Early Signs of Cancer Using tiny crystals called quantum dots, Johns Hopkins researchers have developed a highly sensitive test to look for DNA attachments that often are early warning signs of cancer. St. Jude scientists discover a new mechanism controlling neuronal migration The molecular machinery that helps brain cells migrate to their correct place in the developing brain has been identified by scientists at St. Jude Children's Research Hospital. Ultrasensitive detector promises improved treatment of viral respiratory infections A Vanderbilt chemist and a biomedical engineer have teamed up to develop a respiratory virus detector that is sensitive enough to detect an infection at an early stage, takes only a few minutes to return a result and is simple enough to be performed in a pediatrician's office. More Fluorescent Dyes Current Events and Fluorescent Dyes News Articles |
|||||||||||||||||||||
|
|||||||||||||||||||||
|
|||||||||||||||||||||