Improving the sensitivity for ionic solutes analysis

January 31, 2018

Researchers from Kumamoto University in Japan have developed a new method to improve the sensitivity of analytical systems for various ionic solutes, such as water from rivers, lakes, or even the faucet. Certainly, clean running water is important for community health, and impurity analysis can easily be performed by highly sensitive equipment, such as a mass spectrometer. However, these devices can be prohibitively expensive for low income areas or if only a few samples are to be analyzed. In these cases, an enrichment process is used to improve the sensitivity of more easily accessible analytical systems.

The limits of detection of trace ionic solutes, such as those left over after purification, in drinking water should be at least a few micrograms per liter and even less for ultrapure water used in various industrial processes. There are several different enrichment methods that can be used to increase ionic solute levels in a sample, such as heating with/without a vacuum, nitrogen-flow evaporation, co/precipitation for heavy metal ions, liquid-liquid extraction, solid phase extraction, or electrodialysis, to improve analysis sensitivity.

Researchers used the electrodialytic ion transfer enrichment method since quantitative ion transfer can be achieved and the transferred ions become enriched if the sample solution flow rate is higher than the acceptor solution, i.e., the solution traveling to the analyzer, flow rate. They found that if the flow rate for the sample solution (Fs) was higher than that of the acceptor solution (Fa), the enrichment effect became equivalent to the ratio of the two flow rates (when Fa is not 0), and ion enrichment could be performed in just a few seconds.

Upon testing this enrichment method, researchers found that ion chromatography system detection limits were improved by a factor of ~10 for inorganic cations and ~50 for heavy metal ions, which follows the flow rate ratios of Fs/Fa = 10 and 50 respectively. Similar detection limit results were received in a flow injection analysis (FIA) system. With the present method, the sensitivity of any analytical system can be improved.

Finally, the byproducts of drinking water chlorination, chloroacetic acid (MCAA), dichloroacetic acid (DCAA), and trichloroacetic acid (TCAA) were assessed in Japanese tap water with a HPLC-UV detector using the researcher's electrodialytic enrichment process. The analysis required a relatively higher voltage than that for strong acids to obtain a flow rate ratio of 10, and enrichment factors for the tap water ions averaged an acceptable 9.8.

"Our in-line, real-time, enrichment of ionic solutes improves the sensitivity of testing systems," said Professor Shin-Ichi Ohira, leader of the research project. "What's more, it can be done in just a few seconds. We envision this pretreatment to be implemented in future, fully automated systems."
-end-
This research was published online in the Journal Talanta on 18 Dec. 2017.

[Reference]

Ohira, Shin-Ichi, Takayuki Yamasaki, Takumi Koda, Yuko Kodama, and Kei Toda. "Electrodialytic in-Line Preconcentration for Ionic Solute Analysis." Talanta 180 (April 2018): 176-181. doi:10.1016/j.talanta.2017.12.054.

Kumamoto University

Related Drinking Water Articles from Brightsurf:

The dangers of collecting drinking water
Fetching drinking water in low and middle income countries can cause serious injury, particularly for women.

How a toxic chromium species could form in drinking water
The water crisis in Flint, Michigan, brought much-needed attention to the problem of potentially toxic metals being released from drinking water distribution pipes when water chemistry changes.

Is your drinking water toxic? This app may help you find out
Since fracking sites use a diverse mix of chemical ingredients, often individuals and researchers are in the dark about the health consequences of living near a particular well.

New solar material could clean drinking water
Providing clean water to Soldiers in the field and citizens around the world is essential, and yet one of the world's greatest challenges.

Aluminum may affect lead levels in drinking water
Until recently, researchers have not inspected the interplay between three common chemicals found in drinking water.

Natural contaminant threat to drinking water from groundwater
Climate change and urbanisation are set to threaten groundwater drinking water quality, new research from UNSW Sydney shows.

Fresh clean drinking water for all could soon to be a reality in Pakistan
A fresh, clean water supply will be a reality in Pakistan, particularly in South Punjab, following the announcement of an international partnership spearheaded by the Pakistan government, alongside other key stakeholders, and driven by the University of Huddersfield.

Keeping lead out of drinking water when switching disinfectants
Researchers at the McKelvey School of Engineering at Washington University in St.

Solar power with a free side of drinking water
An integrated system seamlessly harnesses sunlight to cogenerate electricity and fresh water.

'Liquid forensics' could lead to safer drinking water
Ping! The popular 1990 film, The Hunt for Red October, helped introduce sonar technology on submarines to pop culture.

Read More: Drinking Water News and Drinking Water Current Events
Brightsurf.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.