Hot ring produces microwave-powered ultrasound pulses wirelessly

June 23, 2020

Ultrasound imaging is one of the workhorses in a modern hospital. It hits the trifecta of being relatively cheap, portable, and non-invasive. The ability to cause future parents to get a bit emotional over fetus images is also an appreciated perk.

But ultrasound imaging does have its limitations. Its resolution is often limited by the acoustic wavelength, which is rather long, compared to optical wavelengths. This is compounded by the limitations of acoustic transducers: they are typically optimized for a small range of acoustic frequencies, which limits the resolution of time-of-flight type measurements. Then there is the issue of getting sound waves into and out of the body. The large mismatch between the acoustic properties of the human body and air (or a solid microphone) can make for large losses. To overcome this issue, scientists and engineers have come up with some rather creative solutions, like partially immersing the patient in a bath to improve acoustic matching. Being able to place acoustic sources anywhere on the body with good acoustic matching would avoid these problems. But current technology doesn't allow that because the transducers require a bulky power source.

Lan and colleagues, reporting in the peer-reviewed open access journal Advanced Photonics, have developed a wireless ultrasound transducer that is efficiently excited by microwaves. The result is a simple oil-filled patch that can be placed anywhere on the body. No batteries, no wires, and no bath.

Wire loop induces good vibrations
The basic principle is based on using microwave absorption to generate sound waves. Microwaves are an excellent compromise between photoacoustic imaging, which has high-resolution but low imaging depth, and traditional ultrasound imaging. Microwaves result in lower resolution compared to optical systems, but the scattering is also much lower, so excitation depth is no longer a problem. But, the body's absorption of microwaves is also very low, so the generated sound waves are very weak.

The absorbed power is proportional to amplitude of the microwaves. A high amplitude microwave will induce a stronger acoustic wave. The unfortunate side effect is that you may inadvertently cook the person you are imaging. To avoid inadvertent cooking, the microwaves should be concentrated just where they are needed. This is what the device that Lan and colleagues have developed does.

The technique relies on the properties of the split ring resonator. A split ring resonator is a wire loop that is broken. When exposed to microwaves, a current flows in the ring. But, because the ring isn't complete, the charge "piles up" at the gap, creating a large voltage between the ends of the wire. This large oscillating voltage means that, just in the gap, the absorbed power is high, and thermo-elastically induced acoustic waves are produced efficiently.

Now, a resonator implies that it is most efficient at a particular frequency of radiation. Split ring resonators are no exception: the resonant frequency is controlled by the diameter of the wire ring and the medium in which it is placed. Lan and colleagues chose a diameter of about 13 mm, which resonates at about 2.3 GHz in air, and 2.5 GHz in oil. But, the more important feature is the bandwidth of the resonator. Here, the researchers face a choice. To increase the amount of absorbed power, it is beneficial to have a resonator that has a very narrow bandwidth. However, to produce very short pulses of sound, the bandwidth needs to be very broad. The researchers ended up with a split ring resonator with a bandwidth of about 200 MHz, about 10-20 times that of a traditional piezoelectric transducer.

Conformal wireless resonator
The flexibility of the split ring resonator was demonstrated by a series of experiments showing that it could be used to generate mixtures of ultrasound frequencies by pulsing the microwave excitation. Acoustic frequencies up to about 2.5 MHz were produced, but, based on the resonance width of the split ring resonator, higher frequencies can likely be produced.

Probably the biggest benefit is that the resonator is just a copper ring. By placing the ring in a plastic envelope with some oil (the oil absorbs the microwaves and matches the acoustic properties of the body), the ring can be placed anywhere on the body and excited remotely. The researchers demonstrate this using a breast phantom. The ring was placed under the breast, and the detection equipment on top. The wirelessly excited ultrasound signals were strong, and the researchers show that as little as 10mW of average power is required to obtain an ultrasound signal.

Now that the proof of principle has been shown, the next step must be to build an imaging system.
-end-
Read the original research article in the peer-reviewed, open access journal Advanced Photonics: Lan et al., "Ultraefficient thermoacoustic conversion through a split ring resonator," Adv. Photonics 2(3), 036006 (2020), as well as the accompanying commentary by Frederic Cegla, "Microwaves trigger thermo-acoustic ultrasound generation," Adv. Photonics 2(3), 030501 (2020).

Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.



SPIE--International Society for Optics and Photonics

Related Sound Waves Articles from Brightsurf:

Sound waves power new advances in drug delivery and smart materials
Sound waves have been part of science and medicine for decades, but the technologies have always relied on low frequencies.

Scientists make sound-waves from a quantum vacuum at the Black Hole laboratory
Researchers have developed a new theory for observing a quantum vacuum that could lead to new insights into the behaviour of black holes.

Remembrance of waves past: memory imprints motion on scattered waves
Now, it appears that between relativity and the classical (stationary) wave regime, there exists another regime of wave phenomena, where memory influences the scattering process.

Even if you want to, you can't ignore how people look or sound
Your perceptions of someone you just met are influenced in part by what they look like and how they sound.

Scientists achieve major breakthrough in preserving integrity of sound waves
In a breakthrough experiment, physicist and engineers at the CUNY ASRC have shown that it is possible to limit the movement of sound to a single direction without interruption even when there are deformations along the pathway.

Shaking light with sound
Combining integrated photonics and MEMS technology, scientists from EPFL and Purdue University demonstrate monolithic piezoelectric control of integrated optical frequency combs with bulk acoustic waves.

Sound waves transport droplets for rewritable lab-on-a-chip devices
Engineers at Duke University have demonstrated a versatile microfluidic lab-on-a-chip that uses sound waves to create tunnels in oil to digitally manipulate and transport droplets.

A sound treatment
University of Utah biomedical engineering assistant professor Jan Kubanek has discovered that sound waves of high frequency (ultrasound) can be emitted into a patient's brain to alter his or her state.

Light, sound, action: Extending the life of acoustic waves on microchips
Data centres and digital information processors are reaching their capacity limits and producing heat.

Cooling magnets with sound
Today, most quantum experiments are carried out with the help of light, including those in nanomechanics, where tiny objects are cooled with electromagnetic waves to such an extent that they reveal quantum properties.

Read More: Sound Waves News and Sound Waves Current Events
Brightsurf.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.