'sensing skin' detects cracks, harmful chemicals in structures

October 10, 2016

Researchers have developed a multi-layered "sensing skin" to detect corrosive or otherwise harmful substances in structures. The skin can also detect cracks and other structural flaws that are invisible to the naked eye.

"We've created a skin that can be applied to the surface of almost any structure and be used to monitor the structure's integrity remotely and in real time, identifying potential problems long before they become catastrophic," says Mohammad Pour-Ghaz, an assistant professor of civil, construction and environmental engineering at North Carolina State University and co-author of a paper describing the work.

The sensing skin consists of three layers, which can be painted onto the surface of a structure or pre-assembled and attached to the surface like wallpaper.

The first layer is electrically conductive and is used solely to detect cracks. The second layer serves as a buffer between the first and third layers. The third layer detects cracks, but is also engineered to detect specific chemicals of interest.

This third layer incorporates metal nanoparticles whose conductivity changes in the presence of specific ions. By changing the composition of the metal nanoparticles, this layer can be engineered to respond to any particular chemical.

If users want to monitor for chemicals coming out of a structure -- such as leakage of the chemicals out of a containment structure -- the third layer would face inward, touching the structure's surface. To monitor external chemicals, the third layer would face outward.

Here's how the sensing skin works. Electrodes are applied around the perimeter of a structure. The sensing skin is then applied to the structure, over the electrodes. A computer program then runs a small current between two of the electrodes at a time, cycling through a number of possible electrode combinations.

When the current runs between two electrodes, a computer monitors and records the electrical potential at all of the electrodes on the structure for both the first and third layers of the sensing skin. This data is then used to calculate the sensing skin's spatially distributed electrical conductivity on both layers. The researchers have developed a suite of algorithms that can use changes in conductivity measured by the first and third layers of the skin to detect and locate both damage and the presence of target chemicals.

In a proof-of-concept study, the researchers applied their sensing skin to reinforced concrete. The researchers exposed the concrete to corrosive elements and subjected the concrete to strain in order to simulate the failure of real-world structures. For this study, the third layer of the sensing skin was engineered to detect chlorides, which can cause corrosion in reinforced concrete.

"The skin performed really well," Pour-Ghaz says. "We were able to detect cracks as small as a few hundred micrometers; and we could very accurately detect any instances in which chlorides came into contact with the skin.

"We want people to be able to detect problems very early on," Pour-Ghaz says. "And while this proof-of-concept looked at concrete, the technology -- if properly applied -- could be used on structural materials from metals to polymers."

The researchers are in the process of conducting experiments of the sensing skin on a large-scale structure, more accurately reflecting the size of real-world structures.

The paper, "A Functionally Layered Sensing Skin for Detection of Corrosive Elements and Cracking," is published online in the journal Structural Health Monitoring. Lead author of the paper is Aku Seppänen, of the University of Eastern Finland. The paper was co-authored by Milad Hallaji, a former Ph.D. student at NC State. The work was done with support from the Academy of Finland and the Department of Civil, Construction, and Environmental Engineering at NC State.
-end-


North Carolina State University

Related Electrodes Articles from Brightsurf:

Performance test for neural interfaces
Freiburg researchers develop guidelines to standardize analysis of electrodes.

The perfect angle for e-skin energy storage
Researchers at DGIST have found an inexpensive way to fabricate tiny energy storage devices that can effectively power flexible and wearable skin sensors along with other electronic devices, paving the way towards remote medical monitoring & diagnoses and wearable devices.

Vacancy dynamics on CO-covered Pt(111) electrodes
USTC reported in situ video-STM observations of additional point defects in the presence of this dynamic CO adlayer.

Using tiny electrodes to measure electrical activity in bacteria
Scientists at Laboratory of Organic Electronics, Linköping University, have developed an organic electrochemical transistor that they can use to measure and study in fine detail a phenomenon known as extracellular electron transfer in which bacteria release electrons.

Flow-through electrodes make hydrogen 50 times faster
Duke chemists tested three new materials as a porous, flow-through electrode to make hydrogen from electrolysis.

Novel electric impulses relieve the pain
Chronic pain can be reduced by stimulating the vagus nerve in the ear with electrodes.

Visualization of functional components to characterize optimal composite electrodes
Researchers have developed a visualization method that will determine the distribution of components in battery electrodes using atomic force microscopy.

Electrolysis: Chemists have discovered how to produce better electrodes
Another step forward for renewable energies: The production of green hydrogen could be even more efficient in the future.

KIST develops large-scale stretchable and transparent electrodes
A Korean research team has developed a large-scale stretchable and transparent electrode for the stretchable display.

Key progress on the MRI compatible DBS electrodes and simultaneous DBS-fMRI
Recently, collaboration between Dr. Duan Xiaojie's group (Department of Biomedical Engineering, College of Engineering, Peking University) and Dr.

Read More: Electrodes News and Electrodes Current Events
Brightsurf.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.