Some heparin-allergic patients could have urgent heart surgery sooner with combination of appropriate blood screenings and therapeutic plasma exchange

November 18, 2014

Hamilton, ON (Nov. 18, 2014) - McMaster University researchers have found new evidence that suggests patients with a history of adverse reaction to the blood thinner heparin may be ready for urgent heart surgery sooner with a combination of appropriate blood screenings and therapeutic plasma exchange.

The study was published online today in Blood, the journal of the American Society of Hematology. The lead author is Dr. Theodore Warkentin, a professor in the Department of Medicine's Division of Hematology and Thromboembolism and the Department of Pathology and Molecular Medicine at the Michael G. DeGroote School of Medicine.

Many patients taking blood thinners will eventually require some form of heart surgery and will need large quantities of heparin during the surgery to prevent clots. Some patients who have already taken heparin develop antibodies against it, activating platelets and unexpectedly forming clots. This condition is called heparin-induced thrombocytopenia (HIT).

When patients with a history of HIT require urgent heart surgery, physicians must test for the presence of HIT antibodies to see whether the patient can be re-exposed to heparin during the procedure. While HIT antibodies generally go away naturally within several weeks or a few months, levels can sometimes remain high, requiring physicians to take measures to lower them before surgery. To lower these antibodies quickly, a procedure called therapeutic plasma exchange (TPE) is used. Here blood is taken from the patient, plasma is removed, and blood and replacement fluids are returned to the patient's body.

Hematologists use two types of tests to measure HIT antibodies. These include a functional platelet serotonin-release assay and a highly sensitive enzyme-immunoassay. While the functional assay measures release of serotonin, a direct marker of platelet activation, the immunoassay casts a wider net, detecting both clinically significant and insignificant levels of HIT antibodies. The immunoassay is the more widely used of the two tests. If it indicates the presence of HIT antibodies in a patient, surgery is usually delayed or plasma exchange must be performed.

While practitioners have historically understood a clear relationship between the two tests, new research led by Warkentin suggests that the functional assay may show low HIT antibody levels while at the same time an immunoassay result is indicating high levels.

This evidence is summarized in a new case report in which a 76-year-old female with kidney cancer and previous HIT required urgent cardiac surgery to remove a tumor that had spread to her heart. After both her initial functional and immunoassays indicated the presence of HIT antibodies, her doctors decided against surgery. But after repeated TPE, the research team performed both the functional and immunoassays on the patient again and this time observed strikingly different results.

"We were surprised to see that levels of HIT antibodies in this patient fell very quickly according to the functional assay, yet the antibodies detected by the immunoassay remained high," said Warkentin. "This suggested to us that while physicians in many situations may be waiting for the immunoassay to indicate lower antibody levels, patients in urgent need of heart surgery may be ready for it much earlier than the results suggest."

To test the idea and better understand, Warkentin's team developed a model comparing functional and immunoassay results among 15 HIT blood samples, which were diluted and tested with both assays to mimic the effects of repeated TPE. The researchers observed that HIT antibody levels as measured by the functional assay decreased rather quickly, while the immunoassay continued to indicate high levels. This suggests that the sensitivity of the immunoassay may overestimate HIT antibody levels in patients.

The findings support the use of repeated TPE prior to heparin re-exposure among patients with a recent HIT episode who require urgent cardiac surgery.

"Based on these findings, physicians should consider utilizing both of these tests when preparing a patient with a history of HIT for urgent heart surgery, considering the functional assay result as the stronger indicator of a patient's readiness," said Warkentin. "For these patients, TPE can be a useful option to help rapidly reduce their remaining HIT antibody levels, minimize their risk of developing clots, and get them into the operating room sooner."
-end-
Editors: Link to Blood paper http://www.bloodjournal.org/content/early/2014/11/17/blood-2014-07-590844?sso-checked=true

A photo of Dr. Warkentin is attached.

For more information:

Veronica McGuire
Media Relations
Faculty of Health Sciences
McMaster University
vmcguir@mcmaster.ca
905-525-9140, ext. 22169

McMaster University

Related Plasma Articles from Brightsurf:

Plasma treatments quickly kill coronavirus on surfaces
Researchers from UCLA believe using plasma could promise a significant breakthrough in the fight against the spread of COVID-19.

Fighting pandemics with plasma
Scientists have long known that ionized gases can kill pathogenic bacteria, viruses, and some fungi.

Topological waves may help in understanding plasma systems
A research team has predicted the presence of 'topologically protected' electromagnetic waves that propagate on the surface of plasmas, which may help in designing new plasma systems like fusion reactors.

Plasma electrons can be used to produce metallic films
Computers, mobile phones and all other electronic devices contain thousands of transistors, linked together by thin films of metal.

Plasma-driven biocatalysis
Compared with traditional chemical methods, enzyme catalysis has numerous advantages.

How bacteria protect themselves from plasma treatment
Considering the ever-growing percentage of bacteria that are resistant to antibiotics, interest in medical use of plasma is increasing.

A breakthrough in the study of laser/plasma interactions
Researchers from Lawrence Berkeley National Laboratory and CEA Saclay have developed a particle-in-cell simulation tool that is enabling cutting-edge simulations of laser/plasma coupling mechanisms.

Researchers turn liquid metal into a plasma
For the first time, researchers at the University of Rochester's Laboratory for Laser Energetics (LLE) have found a way to turn a liquid metal into a plasma and to observe the temperature where a liquid under high-density conditions crosses over to a plasma state.

How black holes power plasma jets
Cosmic robbery powers the jets streaming from a black hole, new simulations reveal.

Give it the plasma treatment: strong adhesion without adhesives
A Japanese research team at Osaka University used plasma treatment to make fluoropolymers and silicone resin adhere without any adhesives.

Read More: Plasma News and Plasma Current Events
Brightsurf.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.