Bluesky Facebook Reddit Email

Neutron spectroscopy: New detector module MultiFLEXX increases count rate tenfold

12.01.17 | Helmholtz-Zentrum Berlin für Materialien und Energie

SAMSUNG T9 Portable SSD 2TB

SAMSUNG T9 Portable SSD 2TB transfers large imagery and model outputs quickly between field laptops, lab workstations, and secure archives.

Beam time at a neutron instrument is valuable - users generally have only a few days for their measurements. Often, scientists travel from other countries or even continents for an experiment. Naturally, they want to make the most of these days for their research. Therefore, an HZB team at the triple axis spectrometer FLEXX has developed the new detector module MultiFLEXX: It allows beam time to be used ten times as efficiently.

At FLEXX, magnetic excitations and lattice vibrations are measured. They typically have a characteristic relationship of excitations energy and scattering angle. One data point at FLEXX measures exactly one angle and one energy transfer, with a measurement time of several seconds up to several minutes, depending on the sample. To deduce characteristic relationships, many angles and energies need to be measured. The new detector module MultiFLEXX is able to do so with a shorter data collection time: It measures 31 angles and 5 energy transfers simultaneously, being composed of 155 analysers and detectors. Each MultiFLEXX data point has a count rate 5 to 10 times smaller than a single data point at FLEXX - thus, there is a total gain in acquisition efficiency of more than a factor of 10. This is particularly interesting for users who want to map out an excitation as a function of temperature or magnetic field - frequent applications at FLEXX.

The detector module MultiFLEXX was developed by the FLEXX team and assembled in the HZB workshops. It has already been tested successfully in several experiments, both by external users and in the HZB-internal research on thermoelectrics.

###

Scientific Reports

10.1038/s41598-017-14046-z

Keywords

Article Information

Contact Information

Source

How to Cite This Article

APA:
Helmholtz-Zentrum Berlin für Materialien und Energie. (2017, December 1). Neutron spectroscopy: New detector module MultiFLEXX increases count rate tenfold. Brightsurf News. https://www.brightsurf.com/news/8OJRK321/neutron-spectroscopy-new-detector-module-multiflexx-increases-count-rate-tenfold.html
MLA:
"Neutron spectroscopy: New detector module MultiFLEXX increases count rate tenfold." Brightsurf News, Dec. 1 2017, https://www.brightsurf.com/news/8OJRK321/neutron-spectroscopy-new-detector-module-multiflexx-increases-count-rate-tenfold.html.