Bluesky Facebook Reddit Email

Full magnetization hysteresis measurements at MHz frequencies and high magnetic fields

03.30.26 | University of Tsukuba

SAMSUNG T9 Portable SSD 2TB

SAMSUNG T9 Portable SSD 2TB transfers large imagery and model outputs quickly between field laptops, lab workstations, and secure archives.

Tsukuba, Japan—High-frequency magnetic characteristics are essential for improving the efficiency, miniaturization, and operating frequency of power conversion devices such as power supply circuits, inductors, and transformers. However, conventional measurement methods face two major challenges. First, generating sufficiently large magnetic fields at high frequencies requires high power and high voltages. Second, many methods can probe only the initial magnetization region because the achievable magnetic field amplitude is limited. Consequently, reproducing the actual operating environment of next-generation power electronics devices has remained difficult.

In this study, the research team developed a magnetic measurement system capable of accurately measuring the complete M-H loop, including the irreversible magnetization process, up to saturation, even under high-frequency (MHz-band) and high-field (up to 0.5 T) conditions. The system employs a low-impedance LC-resonant excitation coil that can stably generate large-amplitude alternating magnetic fields in the megahertz range. This design enables quantitative and highly reproducible magnetization measurements that were previously unattainable.

Using a commercial Ni-Zn ferrite sample, the researchers successfully obtained a complete M-H loop up to saturation at 1.2 MHz. This result demonstrates that the new system can quantitatively capture the dynamic magnetization behavior of magnetic materials under both high-frequency and large-amplitude magnetic field conditions. These parameters closely match real device operation but were previously difficult to evaluate using conventional techniques. The measurement technique is expected to serve as a foundational tool for advancing next-generation power electronics and to support the design of improved magnetic materials as well as the development of more efficient, compact, and higher-frequency electronic devices.

###
This work was supported by Japan Science and Technology Agency, Adaptable and Seamless Technology transfer Program through target driven R&D (Grant number AS2915014R). This work was partly supported by JST SPRING, Grant Number JPMJSP2124.

Title of original paper:
A Magnetometer for Dynamic Full M-H Loop Measurements in the Megahertz Range

Journal:
IEEE Transactions on Instrumentation and Measurement

DOI:
10.1109/TIM.2026.3659653

Professor YANAGIHARA, Hideto
Institute of Pure and Applied Sciences, University of Tsukuba

Institute of Pure and Applied Sciences

IEEE Transactions on Instrumentation and Measurement

10.1109/TIM.2026.3659653

A Magnetometer for Dynamic Full M–H Loop Measurements in the Megahertz Range

2-Feb-2026

Keywords

Article Information

Contact Information

YAMASHINA Naoko
University of Tsukuba
kohositu@un.tsukuba.ac.jp

Source

How to Cite This Article

APA:
University of Tsukuba. (2026, March 30). Full magnetization hysteresis measurements at MHz frequencies and high magnetic fields. Brightsurf News. https://www.brightsurf.com/news/LN2P5ZM1/full-magnetization-hysteresis-measurements-at-mhz-frequencies-and-high-magnetic-fields.html
MLA:
"Full magnetization hysteresis measurements at MHz frequencies and high magnetic fields." Brightsurf News, Mar. 30 2026, https://www.brightsurf.com/news/LN2P5ZM1/full-magnetization-hysteresis-measurements-at-mhz-frequencies-and-high-magnetic-fields.html.