Machine learning calibration of biosensors for microcystin toxin monitoring in freshwater

07.10.26 | Hanbat National University Industry–University Cooperation Foundation

Kestrel 3000 Pocket Weather Meter

Kestrel 3000 Pocket Weather Meter measures wind, temperature, and humidity in real time for site assessments, aviation checks, and safety briefings.


Portable screen-printed carbon electrode (SPCE) biosensors offer a rapid and low-cost way to detect microcystin-lysine-arginine (MC-LR), an extremely potent toxin produced by cyanobacteria during harmful algal blooms in freshwater. Even at low concentrations, MC-LR can damage the liver and has been linked to an increased risk of liver and colon cancer and the World Health Organization has set a guideline value of 1 microgram per liter for MC-LR in drinking water.

SPCE sensors work by measuring changes in an electrochemical signal that reflects the toxin's concentration. However, the accuracy of these sensors is strongly affected by the water being tested. Factors such as pH, turbidity, electrical conductivity, and other water quality parameters can interfere with the sensor's readings, often requiring recalibration for each water sample.

Researchers from Hanbat National University, South Korea, and the University of Central Florida, USA, have developed a machine learning framework that accounts for water quality differences, enabling accurate MC-LR measurements without repeated sample-specific calibration. The study was led by Professor Jungsu Park from Hanbat National University and Professor Woo Hyoung Lee from the University of Central Florida. This paper was made available online on 26 March 2026 and was published in Volume 298 of the journal Water Research on 15 June 2026.

"This work provides a robust data-driven framework for characterizing biosensor-water matrix interactions and offers a practical approach to improving the speed and accuracy of on-site MC-LR detection in complex environmental waters," says Prof. Park.

To build and train the model, the team collected 201 measurements from 27 field sites across Florida, including freshwater, estuarine, and transitional environments, representing a wide range of water conditions. For each water sample, they measured pH, turbidity, electrical conductivity, total dissolved solids, ultraviolet absorbance at 254 nanometers (UV 254 ), and the biosensor's electrochemical impedance (Z’), which changes in response to MC-LR. These measurements served as the input variables, while the model was trained to predict the actual concentration of MC-LR.

Among the various machine learning models evaluated, Extreme Gradient Boosting (XGBoost) performed the best, achieving a Nash-Sutcliffe efficiency of 0.89 and a root mean square error of 13.21. This level of performance demonstrated that a single unified model could accurately predict MC-LR concentrations across different water samples without requiring separate calibration models for each condition.

To identify which input variables had the greatest influence on the model's predictions, the researchers used an explainable artificial intelligence method called Shapley Additive Explanations (SHAP). They found that the biosensor's electrical impedance was the strongest predictor of toxin levels, followed by electrical conductivity, pH, ultraviolet absorbance, and turbidity, showing that incorporating water quality parameters improves the accuracy of biosensor predictions.

"This framework eliminates the need for repeated sample-specific calibration, reducing time, labor, and sensor consumption. Compared to conventional workflows, it can reduce sensor usage and thereby lowering cost and environmental burden while improving analytical efficiency ," says Prof. Park.

As harmful algal blooms become more frequent with climate change, this data-driven approach could make toxin monitoring faster, more accurate, and easier to deploy in drinking and recreational water testing.

Reference
Title of original paper: Calibration-free on-site detection of microcystin-LR using integrated biosensing, multi-parameter water quality monitoring, and machine learning
Journal: Water Research
DOI: https://doi.org/10.1016/j.watres.2026.125832

About Hanbat National University (HBNU)
Hanbat National University (HBNU) is a public university in Daejeon, South Korea, with origins dating back to 1927 as the Hongseong Public High School of Engineering Training. Renamed Hanbat National University in 2023, it has built a strong reputation for engineering, technology, and industry–academia collaboration. The university is recognized for its extensive partnerships with industry and its role in advancing innovation through applied research and technology transfer. HBNU has been selected for several major national higher education initiatives, including industry–academic cooperation and university innovation programs. Guided by its vision of becoming a "Global Standard University of Industrial Innovation," HBNU aims to strengthen its international competitiveness.
https://www.hanbat.ac.kr/eng/sub01_04.do

About Professor Jungsu Park from Hanbat National University
Professor Jungsu Park is a researcher in environmental engineering at Hanbat National University in Daejeon, South Korea. He has authored more than 40 scientific publications. His research focuses on the application of artificial intelligence to water environment management, including water quality and algal bloom prediction, water treatment process management, and PFAS analysis. His work includes the development of machine learning approaches, such as ensemble learning and deep learning models, including Generative Adversarial Networks, to support water environment management.

Water Research

10.1016/j.watres.2026.125832

Experimental study

Not applicable

Calibration-free on-site detection of microcystin-LR using integrated biosensing, multi-parameter water quality monitoring, and machine learning

15-Jun-2026

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Keywords

Article Information

Contact Information

Seyoung Jang
Hanbat National University Industry–University Cooperation Foundation
j56884@hanbat.ac.kr

Source

How to Cite This Article

APA:
Hanbat National University Industry–University Cooperation Foundation. (2026, July 10). Machine learning calibration of biosensors for microcystin toxin monitoring in freshwater. Brightsurf News. https://www.brightsurf.com/news/1EO9M7OL/machine-learning-calibration-of-biosensors-for-microcystin-toxin-monitoring-in-freshwater.html
MLA:
"Machine learning calibration of biosensors for microcystin toxin monitoring in freshwater." Brightsurf News, Jul. 10 2026, https://www.brightsurf.com/news/1EO9M7OL/machine-learning-calibration-of-biosensors-for-microcystin-toxin-monitoring-in-freshwater.html.