Bluesky Facebook Reddit Email

ARRS Annual Meeting: 4D flow MRI, 3D phantoms benefit atrial fibrillation patients

04.17.23 | American Roentgen Ray Society

GQ GMC-500Plus Geiger Counter

GQ GMC-500Plus Geiger Counter logs beta, gamma, and X-ray levels for environmental monitoring, training labs, and safety demonstrations.


Honolulu, HI | April 17, 2023— Findings from an award-winning Scientific Online Poster presented during the 2023 ARRS Annual Meeting at the Hawaiian Convention Center suggest that correctly occluded left atrial appendages (LAAs) could present maximal reduction in left atrial (LA) flow stasis and thrombogenicity, offering a clinical goal for the procedure in patients with atrial fibrillation.

Pointing out the paucity of knowledge in atrial fibrillation (AF) populations regarding the actual flow dynamic changes before and after percutaneous left atrial appendage occlusion (LAAO), “we aimed to evaluate LA flow dynamics for pre-occluded, correctly occluded, and incorrectly occluded LAAs in patients with AF via four-dimensional (4D) flow MRI and 3D printed phantoms,” said Min Jae Cha from the department of radiology at Chung-Ang University Hospital in Seoul, South Korea.

In this ARRS Annual Meeting Summa Cum Laude award-winning Online Poster , life-sized LA phantoms of an 86-year-old patient with persistent AF were 3D printed from cardiac CT images. Setting a custom-made, closed-loop flow circuit, a pump delivered pulsatile pulmonary venous flow. Using a 3-T scanner (Philips Achieva TX), 4D flow MRI was obtained, then analyzed via MATLAB-based software. Flow metrics associated with blood stasis and thrombogenicity—stasis volume defined by velocity threshold (|V| < 3 cm/s), time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP)—were compared among three conditions.

According to Cha et al., different spatial distributions, orientations, and magnitudes of flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and percentage of LA flow stasis were consistently minimized in the correctly occluded model (70.82 ml, 38.97%), followed by the incorrectly occluded (73.17 ml, 39.02%) and pre-procedural (79.11 ml, 39.71%) models.

Additionally, the pre-occluded model was associated with the lowest surface-and-time-averaged WSS (0.048 Pa), followed by incorrectly (0.059 Pa) and correctly (0.072 Pa) occluded models. Conversely, ECAP was lowest in the correctly occluded model (4.004 Pa-1), followed by the incorrectly- (4.792 Pa-1) and pre-occluded (5.861 Pa-1) models.

North America’s first radiological society, the American Roentgen Ray Society (ARRS) remains dedicated to the advancement of medicine through the profession of medical imaging and its allied sciences. An international forum for progress in radiology since the discovery of the x-ray, ARRS maintains its mission of improving health through a community committed to advancing knowledge and skills with the world’s longest continuously published radiology journal— American Journal of Roentgenology —the ARRS Annual Meeting, InPractice magazine, topical symposia, myriad multimedia educational materials, as well as awarding scholarships via The Roentgen Fund ®.

MEDIA CONTACT :

Logan K. Young, PIO

44211 Slatestone Court

Leesburg, VA 20176

lyoung@arrs.org

Imaging analysis

People

N/A

Keywords

Article Information

Contact Information

Logan Young
American Roentgen Ray Society
lyoung@arrs.org

Source

How to Cite This Article

APA:
American Roentgen Ray Society. (2023, April 17). ARRS Annual Meeting: 4D flow MRI, 3D phantoms benefit atrial fibrillation patients. Brightsurf News. https://www.brightsurf.com/news/LRDMX6O8/arrs-annual-meeting-4d-flow-mri-3d-phantoms-benefit-atrial-fibrillation-patients.html
MLA:
"ARRS Annual Meeting: 4D flow MRI, 3D phantoms benefit atrial fibrillation patients." Brightsurf News, Apr. 17 2023, https://www.brightsurf.com/news/LRDMX6O8/arrs-annual-meeting-4d-flow-mri-3d-phantoms-benefit-atrial-fibrillation-patients.html.